CGGNK - SAVACARB MTCI THERMAL BLACK

  • MSDS: CGGNK
  • Manufacturer: COLUMBIA CHEMICALS CO
  • Product Name: SAVACARB MTCI THERMAL BLACK
  • National Stock Number: 6810-00N078784
Product Identification

Product ID:SAVACARB MTCI THERMAL BLACK
MSDS Date:11/22/1993
FSC:6810
NIIN:00N078784
MSDS Number: CGGNK

Responsible Party
COLUMBIA CHEMICALS CO
1600 PARKWOOD CIRCLE
ATLANTA, GA 30339
US

Emergency Phone: 800-235-4003

Info Phone: 404-951-5700

Cage: IO316

Contractor
COLUMBIAN CHEMICALS CO
ATLANTA, GA 30339 US

Telephone: 404-953-7801

Cage: 43376

Ingredients

CARBON BLACK

CAS: 1333-86-4

RTECS: FF5800000

Fraction By Weight: 100%

OSHA PEL 3.5 MG/M3

ACGIH TLV: 3.5 MG/M3


EXPOS TO OTHER AGENTS, E.G. CARBON MONOXIDE, COAL

RTECS: 9999999ZZ


WERE FAR IN EXCESS OF VALUES FOUND IN U.S. & W.

RTECS: 9999999ZZ


FIBROSIS & LUNG TUMORS HAVE BEEN FOUND IN RATS

RTECS: 9999999ZZ


CONCS OF CARBON BLACK & OTHER INSOL DUST PARTICLES

RTECS: 9999999ZZ


WHO CONDUCTED THESE TESTS BELIEVE THESE DISEASES MOST

RTECS: 9999999ZZ


IN LUNG, THE "LUNG OVERLOAD PHENOMENON," RATHER THAN

RTECS: 9999999ZZ


OCCUR ONLY WHEN LUNGS ARE OVERLOADED W/EXCESS OF SM

RTECS: 9999999ZZ


EXPOSURE TO CARBON BLACK AT OR BELOW THE TLV CAUSES

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE:DUST CONCS ABOVE PEL EXPOSURE
LIMIT MAY CAUSE TEMPORARY UPPER RESPIRATRY TRACT DISCOMFORT.
CHRONIC:COMMERCIALLY PRDCED CARBON BLACK IS DESIGNATED AS NUISANCE
DUST BY ACGIH-TLV COMMITTEE, PRODUCI NG NO EVID OF PATHOLOGICAL/
RESTRICTIVECHGS IN LUNG ARCHITECTURE/FUNC. NO CARCIN EFT HAS BEEN
FOUND (EFTS OF OVEREXP)
Explanation of Carcinogenicity:CARBON BLACK:IARC MONO ON EVAL OF CARCIN
RISK OF CHEMS TO MAN, VOL 65, PG 24-27; 1995:GROUP 2B.
Effects of Overexposure:HLTH HAZ:IN ANIMALS/HUMANS DUE TO EXPOS TO
COMMERCIAL CARBON BLACK. CARBON BLACK DOES CONTAIN TRACE AMTS OF
STRONGLY ABSORBED POLYNUCLEAR AROMATIC CMPDS (PNA'S). SOME PNA'S IN
NON-ABSORBED FORM HAVE B EEN FOUND TO BE CARCIN. EPIDEMIOLOGY
STUDIES OF U.S. & W. EUROPEAN CARBON BLACK WORKERS SHOW NO
SIGNIFICANT HLTH)(SUPDAT
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INGEST:CALL MD IMMEDIATELY . INHAL:REMOVE TO FRESH AIR.
EYES:FLUSH WITH PLENTY OF WATER, OCCASNLY LIFTING LOWER & UPPER
LIDS FOR @ LST 15 MINS. SKIN:WASH WITH WATER & MILD SOAP/WATERLESS
HAND CL EANER TO REMOVE CARBON BLACK DUST.

Fire Fighting

Extinguishing Media:WATER SPRAY. AUTOIGNITION TEMPERATURE:IGNITION IN
AIR ABOVE 500F. MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . NORMAL FOG OR NOZZLE JET APPLICATION AND/OR EXCLUSION
OF AIR.
Unusual Fire/Explosion Hazard:NONE. CARBON MONOXIDE AND CARBON DIOXIDE
ARE EMITTED. IT MAY NOT BE OBVIOUS THAT CARBON BLACK IS BURNING
UNLESS IT IS STIRRED AND SPARKS ARE APPARENT.

Accidental Release

Spill Release Procedures:VACUUM, SWEEP OR SPRAY WITH WATER AND COLLECT
IN A SUITABLE CONTAINER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:KEEP IN CLOSED CONTAINERS. TEST FOR
CARBON MONOXIDE AND OXYGEN BEFORE ENTRY INTO CONFINED SPACES.
Other Precautions:USE APPROP NIOSH APPRVD RESP/AIR LINE FOR POSSIBLE
EXPOSURE TO CARBON MONOXIDE, CARBON DIOXIDE & INADEQUATE OXYGEN
CONTENT IF TEST RESULTS SO INDICATE.

Exposure Controls

Respiratory Protection:NIOSH APPROVED DUST MASK ABOVE TLV/PEL.
Ventilation:USE GUIDELINES REC BY AMERICAN CONFERENCE OF GOVT INDUST
HYGIENISTS IN CURRENT EDITION OF "INDUST VENT: CONSIDERING TLV.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPRVD EYE WASH & DELUGE SHOWER .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
SPEC GRAV:1.7-1.9 (WATER =1). EFTS OF OVERXP:EFTS DUE TO OCCUP EXPOS.
EARLIER STUDIES IN U.S.S.R. & E. EUROPE RPT ON HIGH INCIDENCE OF
RESP DISEASE, INCL PNEUMOCONIOSIS, EMPHYSEMA & RHINITIS. THESE ST
UDIES ARE OF QUESTIONALBLE VALIDITY DUETO POOR DESIGN & METHODOLOGY
& LACK OF ADEQ CTLS TO ACCOUNT FOR EFT OF (ING 2)

Chemical Properties

Spec Gravity:SUPDAT
Solubility in Water:NEGLIGIBLE
Appearance and Odor:AMORPHOUS, BLACK SOLID, ODORLESS.

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS SUCH AS CHLORATES, BROMATES AND NITRATES.
Stability Condition to Avoid:EXCESSIVE HEAT AND STRONG OXIDIZERS SUCH
AS CHLORATES, BROMATES AND NITRATES.
Hazardous Decomposition Products:CARBON MONOXIDE AND CARBON DIOXIDE
WHEN BURNING.

Disposal

Waste Disposal Methods:BURY OR BURN IN ACCORDANCE WITH LOCAL, STATE AND
FEDERAL REGULATIONS. CARBON BLACK IS NOT A HAZARDOUS WASTE.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their